with FREE UK Standard Delivery
The SpaceLogger.W100 data logger is an ethernet connected logger that is compatible with the Gill WindSonic, MaxiMet, MetPak, LCJ Capteurs CV7 and Calypso ultrasonic range of sensors with 2*RS232 or 1*RS232 & 1*RS422/485 input enabling the simultaneous live viewing and recording of data from two sensors on WeatherFile.com.
![]() 24 HOUR SHIPPING
Processing Mon-Frion all in-stock models |
![]() FREE UK DELIVERY
Free standard deliveryNext day delivery available |
![]() RETURN POLICY
Not 100% satisfied?Return within 21 days |
The SpaceLogger.W100 data logger is an ethernet connected logger for enabling the simultaneous live viewing and recording of data from two wind, weather or environmental sensors on WeatherFile.com. Compatible with wind, weather and environmental sensors from Gill Instruments, LCJ Capteurs and Calypso, the SpaceLogger W100 logger accommodates RS232, RS422 and RS485 inputs.
Please contact us if you have a sensor requiring an ethernet connected data logger, we work with manufacturers delivering OEM and retrofit solutions.
The logger has two programmable switchable alarm signal outputs on each sensor's channel available to trigger audible and visual alarms. Data from each channel can be sampled at up to 1Hz with each data record, date and time-stamped when stored. Each day a new file (.CSV) file is generated, logged on an internal SD card and automatically transferred to WeatherFile.com. Data is held on the SD card and If for any reason the loggers ethernet connection is temporarily unavailable it will automatically transfer to WeatherFile.com once the connection is restored.
Raw data averaged values with min and max readings during a specified period can be recorded in a separate daily .CSV file.
Email and SMS alerts can be set up by the user on Weatherfile.com to warn when wind speed thresholds have exceeded a defined level.
• Weather monitoring/warnings
• Environmental monitoring
• Dust, noise and vibration monitoring
• High rise building external areas
• Aviation operations
• Sports & outdoor activities
• Temporary structure monitoring
• Construction industry H & S
• Education and Research projects
• Agriculture & Horticulture
• HVAC monitoring
• Bridges & tunnels
• Continuous, automatic recording of data from wind speed,
wind direction, weather and environmental sensors
• Ethernet data transfer to WeatherFile.com for viewing live and historic data
• 2 ports for RS232/422/485 inputs
• Two user programmable switchable alarm signals available per sensor channel
• Real-time clock, with battery back-up, for date and time stamping of data
• Compact, economical and robust design
Physical | Dimensions |
Width: 100 mm Depth: 80 mm Height: 22 mm |
Weight | 100g | |
Enclosure material | ABS with polycarbonate cover | |
Mounting | 35mm DIN rail mount, plus optional abs base plate mount | |
Serial Data Input | Number of channels | 2 |
Transmission standard | Port 1: RS232 or RS422/485, Port 2: RS232 | |
Transmission speed | 2,400 to 115,200 baud | |
Flow control | Port 1: Hardware (RTS/CTS) or software flow control | |
Connection | OEM specific: 14-way pluggable terminal block, 9-way D-type | |
LAN Connectivity | Wired connection | RJ45 connector 10/100 Base-T |
Switch output | Switch output | 2 programmable per channel |
Data Storage | Data storage card | Removable micro SDHC/SDXC card |
Data capacity |
Capacity of micro SDHC/SDXC card installed (max. 2TB) 8Gb micro SDHC supplied as standard |
|
Card removal | Buffer purge button | |
Audible / Visual Indicators |
LED Indicators |
Micro SDHC card status: Bi-colour red/green Data/LAN connectivity status: Bi-colour red/green |
Audio Bleeper | Status alert | |
Real Time Clock | Accuracy | ±40 ppm at 25°C |
RTC back-up battery | CR2032 | |
Power | Power requirement | 5 Vdc ±10% |
Current at 5Vdc | 200 mA typical | |
Connection | Micro USB connector | |
Environmental | Temperature range | Operating: -25°C to +70°C Storage: -40°C to +70°C CE marked - EMC directive 2014/30/EC |
Emissions |
EN 55032:2015 CISPR 32:2015, Class B | EN 60945:2002 CISPR 16-1:1999, Class B | EN 61000-3-2:2014 Class A | EN 61000-3-3:2013 FCC/CFR 47: Part 15:2017 ANSI C63.4:2014, Class A Canadian Standard ICES-003:Issue: CISPR 22:2008 |
|
Immunity |
EN 55024:2010 | EN 61000-4-2:2009, EN 61000-4-3:2006 incl A1:2008 & A2:2010, EN 61000-4-4:2012, EN 61000-4-5:2012, EN 61000-4-6:2014, EN 61000-4-11:2010
WEEE Directive 2012/19/EU RoHS Directive 2011/65/EU |
|
Guarantee | Period | 1 year warranty |
Data Sheet | |
---|---|
![]() |
SpaceLogger W100 - Data Sheet |
Industrial Emissions Monitoring Data | |
|
|
Milk Pasteurizer Machine Data Back-up | |
Why this logger is so critical is that the normal method of recording the data requires a degree of manual interaction, and if this does not occur for some reason, the entire batch cannot be sold due to the lack of pasteurization data. |
Gwennap Head National Coastwatch Weather Station | |
Richard Paul Russell has provided a complete internet connected weather station utilising a SpaceLogger W50 for the National Coastwatch Institution at Gwennap Head in Cornwall. The Gill Metpak weather sensor data is captured by the W50 data logger enclosed in the WeatherFile Connection Unit (WCU) and then transferred via the W50's Wi-Fi module to the Local area network and the internet. The live and historic wind speed, wind direction, pressure, temperature and humidity data can then be viewed on any internet connected device via the WeatherFile website. Richard Paul Russell have over 70 weather systems all using SpaceLogger W50s viewable on the WeatherFile website. |
|
Ryde Pier, Isle of Wight, Wind Data | |
This takes the Solent WeatherFile network to five sites and is an essential resource for sailors, water sport enthusiasts, sailing event organisers and others wishing to have live and accurate wind speed and direction measurements. One of the main challenges faced when fitting this unit was to overcome the lack of a local power supply and Wi-Fi internet access. Our newly developed WeatherFile Mobile Unit (WMU) containing a W50 and associated 4G router allows data to be gathered directly from the Gill MaxiMet GMX200 sensor and sent to our WeatherFile website. This was locally powered through a deep cycle leisure battery (70Ahr) connected to a solar panel. The result is cable free live data through WeatherFile completely independent of mains power and local internet. |
Mapping Conditions & Life on the Sea Bed | |
The SpaceLogger S10 data loggers were part of the equipment on three 3000 metre depth rated 'pods' along with batteries, video processing equipment and control electronics. Marcus Shirley of Mr ROV, a member of the research team, confirmed back to us: "The loggers worked great and allowed us to reliably record accurate data which we were able to easily import into our scienfic modelling software. The time stamping feature allowed us to sync up all the data with the logged data from the ship's GPS and vehicle USBL position transponder, creating a very comprehensive data set. Many thanks for your help. The SpaceLogger S10 data loggers were great and 100% reliable, which is very important when you're on a ship far from land!" |
|
New Zealand Lamb Weighing System | |
|
|
Straits of Malacca & Singapore Shipping Data | |
|
|
Vehicle Activated Signs Data | |
|
|
Bombardier Transportation Rail Vehicle Data | |
|
|
Load Cells with 4-20mA Output | |
The SpaceLogger A10 may take up to two 4-20mA analogue output. Readings are sampled at 75Hz, averaged over 1 second and time and date stamped when stored. The SpaceLogger A10 can be daisy chained for multiple load cell monitoring. Data is captured in a daily .csv file for easy analysis within a spreadsheet. If required conditional logging can be utilised. |
|
Outside Webcasting Services | |
|
|
Manufacturing Quality Control For Water Softener Filters | |
|
Warehouse Loading Bay Wind Data | |
|
|
Industrial Emissions Monitoring Data | |
|
|
Gwennap Head National Coastwatch Weather Station | |
Richard Paul Russell has provided a complete internet connected weather station utilising a SpaceLogger W50 for the National Coastwatch Institution at Gwennap Head in Cornwall. The Gill Metpak weather sensor data is captured by the W50 data logger enclosed in the Weatherfile Connection Unit (WCU) and then transferred via the W50's Wi-Fi module to the Local area network and the internet. The live and historic wind speed, wind direction, pressure, temperature and humidity data can then be viewed on any internet connected device via the WeatherFile website. Richard Paul Russell have over 50 weather systems all using SpaceLogger W50s viewable on the WeatherFile website. |
|
Ryde Pier, Isle of Wight, Wind Data | |
This takes the Solent WeatherFile network to five sites and is an essential resource for sailors, water sport enthusiasts, sailing event organisers and others wishing to have live and accurate wind speed and direction measurements. One of the main challenges faced when fitting this unit was to overcome the lack of a local power supply and Wi-Fi internet access. Our newly developed WeatherFile Mobile Unit (WMU) containing a W50 and associated 4G router allows data to be gathered directly from the Gill MaxiMet GMX200 sensor and sent to our WeatherFile website. This was locally powered through a deep cycle leisure battery (70Ahr) connected to a solar panel. The result is cable free live data through WeatherFile completely independent of mains power and local internet. |
|
Scottish Airport Cloud Ceilometer Data | |
This development has allowed Richard Paul Russell to enter the small airfield market with equipment system supply for comprehensive live wind, weather and visibility data. |
Eschmann Technologies Dental Autoclave Real-Time Cycle Data Management | |
The hardware customisation was in the areas of enclosure, brand labelling and over-moulded cable assembly. The software development was extensive to interpret the cycle data, allow manual input of additional tests and checks, facilitate user data analysis and present the combined data in the desired summary and detailed formats including Eschmann branded pdfs. This was a relatively complex project that has provided Eschmann customers with an on-going very successful product, that is still standing the test of time some 10 years after first use. |
|
Prestige Medical's Dental Decontamination Autoclave Cycle Logging | |
The most recent customisation was for a re-designed PCB-only logger to be built-in to a new autoclave design, with particular requirements for the SD card interface with the autoclave control panel fascia. This involved a new PCB layout to accommodate several changes including a new push-push SD card connector. |
|
MDS Medical's Dental & Veterinary Autoclave Data Management System | |
|
|
Large Scale Plasma Sterilizer Data | |
The data logger is shipped to Renosem's manufacturing facility as PCB-only for internal fitting in their plasma sterilizers. The SD card, LED indicators and purge button are all accessible through a faceplate in the outer casing of the sterilizer. The data is saved in daily text files, replicating the format that would be seen on a traditional paper printer-out. |
Eschmann Technologies Dental Autoclave Real-Time Cycle Data Management | |
The hardware customisation was in the areas of enclosure, brand labelling and over-moulded cable assembly. The software development was extensive to interpret the cycle data, allow manual input of additional tests and checks, facilitate user data analysis and present the combined data in the desired summary and detailed formats including Eschmann branded pdfs. This was a relatively complex project that has provided Eschmann customers with an on-going very successful product, that is still standing the test of time some 10 years after first use. |
|
Warehouse Loading Bay Wind Data | |
The W100 with a wired LAN connection is particularly valuable for safety critical applications such as this, and also where Wi-Fi is unreliable. |
|
On-board Vehicle Bin Weighing Systems | |
Further developments in this area have included Wi-Fi connectivity to allow direct data transfer as soon as soon as refuse or grit/salt spreader vehicles return to base. |
|
Mettler Toledo Laboratory Weigh Scales | |
The SpaceLogger T10 model is ideal for balances with a print command and RS232 output and will keep a text record identical to the paper print-out. Hence the requirement for a dedicated printer on the lab bench is removed. |
|
Prestige Medical's Dental Decontamination Autoclave Cycle Logging | |
The most recent customisation was for a re-designed PCB-only logger to be built-in to a new autoclave design, with particular requirements for the SD card interface with the autoclave control panel fascia. This involved a new PCB layout to accommodate several changes including a new push-push SD card connector. |
|
Scottish Airport Cloud Ceilometer Data | |
This development has allowed Richard Paul Russell to enter the small airfield market with equipment system supply for comprehensive live wind, weather and visibility data. |
|
MDS Medical's Dental & Veterinary Autoclave Data Management System | |
|
|
Large Scale Plasma Sterilizer Data | |
The data logger is shipped to Renosem's manufacturing facility as PCB-only for internal fitting in their plasma sterilizers. The SD card, LED indicators and purge button are all accessible through a faceplate in the outer casing of the sterilizer. The data is saved in daily text files, replicating the format that would be seen on a traditional paper printer-out. |