RPR
 
Menu
Kestrel 5000AG Livestock Environmental Meter Kestrel 5000AG Livestock Environmental Meter Kestrel 5000AG Livestock Environmental Meter
5-Year Warranty on all Kestrels

Kestrel 5000AG Livestock Environmental Meter

Product code: K5000 - 0850

£ inc. VAT ex VAT)

A must-have tool for livestock producers, veterinarians and handlers.

Features
• Pocket-sized & rugged
• Accurate meter for assessing ventilation effectiveness, barn conditions, livestock heat stress, air speed, field microclimates, storage conditions, transportation safety, and more.


24 HOUR SHIPPING
Processing Mon-Fri
on all in-stock models
FREE UK DELIVERY
Free standard delivery
Next day delivery available
RETURN POLICY
Not 100% satisfied?
Return within 21 days

Product code: K5000AG

Kestrel 5000AG Livestock Environmental Meter Overview

The Kestrel 5000AG is designed to meet the needs of livestock, agriculture and animal health professionals. Producers, growers, veterinarians, and consultants in every field of agriculture will gain vital information regarding micro-climate conditions needed to maximize performance and profitability. This lightweight, handheld, multi-function meter can be used inside and out for spot measurement of current conditions and also tracks and logs over 10,000 sets of time-stamped data. Clip the Kestrel 5000AG into the custom Kestrel 5 Series Rotating Vane Mount and you have a sturdy weather station that can be left in place for days or weeks.

Heat Stress Management with THI:

THI, (Temperature-Humidity Index) has been used for decades as a measure to classify heat stress risk in many livestock production and transportation operations. This measurement includes both temperature and relative humidity and is a basis for both strategic and tactical management practices which benefit animal health, productivity and well-being. The Kestrel 5000AG calculates and logs on-site THI based on user selection of either the NRC(National Research Council, 1971) or Yousef(Yousef, 1985) accepted THI calculations. Objective and accurate site-specific measurements are critical to ensuring a heat stress management strategy that is cost effective; and they're at your fingertips with the 5000AG.

Sensor Accuracy (+/-) Resolution Specification Range Notes
Wind Speed | Air Flow Larger of 3% of reading, least significant digit or 20 ft/min 0.1 m/s
1 ft/min
0.1 km/h
0.1 mph
0.1 knots
1 B*
0.1 F/S*
0.6 to 40.0 m/s
118 to 7,874 ft/min
2.2 to 144.0 km/h
1.3 to 89.5 mph
1.2 to 77.8 knots
0 to 12 B*
2-131.2*
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min| 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5° off-axis; -2% @ 10°; -3% @ 15°. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller.
*F/S only in Ballistics units. Beaufort not available in Ballistics units.
Ambient Temperature 0.9 °F
0.5 °C
0.1 °F
0.1 °C
-20.0 to 158.0 °F
-29.0 to 70.0 °C
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits
Relative Humidity ±2%RH 0.1 %RH 10 to 90% 25°C non-condensing To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.
Pressure ±1.5 mbar at 25°C, 700-1100 mbar/ ±0.044inHg at 77°F 20.67-32.48 inHg/
±0.022 PSI 10.15-15.95 PS
0.01 inHg
0.1 hPa|mbar
0.01 PSI
25°C/77°F,
700-1100 mbar/20.67-32.48 inHg/10.15-15.95 PSI
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Between 1100–1200 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1200 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.

 

Calculated Measurements

Measurement Accuracy (+/-) Resolution Sensors Deployed
Air Density 0.0002 lb/ft3
0.0033 kg/m3
0.001 lbs/ft3
0.001 kg/m3
Temperature Relative
Humidity Pressure
Air Flow 6.71% 1 cfm
1 m3/hr
1 m3/m
0.1m3/s
1 L/s
Air Flow
User Input (Duct Shape & Size)
Altitude typical: 23.6 ft/7.2 m - 50 to 1100 mBar
max: 48.2 ft/14.7 m – 300 to 750 mBar
1 ft
1 m
Pressure
User Input (Reference Pressure)
Barometric Pressure 0.07 inHg
2.4 hPa|mbar
0.03 PSI
0.01 inHg
0.1 hPa|mbar
0.01 PSI
Pressure
User Input (Reference Altitude)
Density Altitude 226 ft
69 m
1 ft
1 m
Temperature Relative
Humidity Pressure
Dew Point 3.4 °F
1.9 °C
15-95% RH. Refer to Range for Temperature Sensor
0.1 °F
0.1 °C
Temperature Relative
Humidity
Evaporation Rate 0.01 lb/ft2/hr
0.06 kg/m2/hr
0.01 b/ft2/hr
0.01 kg/m2/hr
Wind Speed Temperature Relative Humidity Pressure User Input (Concrete Temperature)
Heat Index 7.1°F
4.0°C
0.1 °F
0.1 °C
Temperature Relative Humidity
Moisture Content | Humidity Ratio (“Grains”) .3gpp
.4g/kg
0.1 gpp
0.01 g/kg
Temperature Relative Humidity Pressure
Relative Air Density 0.3% 0.1% Temperature Relative Humidity Pressure
Wet Bulb Temperature - Psychrometric 3.2 °F
1.8 °C
0.1 °F
0.1 °C
Temperature Relative Humidity Pressure
Wind Chill 1.6 °F
0.9 °C
0.1 °F
0.1 °C
Wind Speed Temperature

 

Additional Product Info

Display & Backlight Multifunction, multi-digit monochrome dot-matrix display. Choice of white or red LED backlight.
Response Time & Display Update Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity.
Data Storage & Graphical Display, Min/Max/Avg History Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points.
Data Upload & Bluetooth® Data Connect Option Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC).
Clock / Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Auto Shutdown User-selectable – Off, 15-60 minutes with no key presses.
Languages English, French, German, Spanish.
Certifications CE certified, RoHS and WEEE compliant. Individually tested to NIST-traceable standards.
Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery Life AA Lithium, included. Up to 400 hours of use, reduced by backlight or Bluetooth radio transmission use.
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.5 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6)
Display & Battery Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading
Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight 5.0 x 1.9 x 1.1 in / 12.7 x 4.5 x 2.8 cm, 4.3 oz / 121 g. (Lithium battery included)